新产品!RnD VisUCyte Cell and Tissue Staining Kits(细胞组织染色试剂盒)

浏览次数:437

分享:

R&D systems 新推出 VisUCyteTM Cell and Tissue Staining Kits(细胞组织染色试剂盒)! 

 

相比较于传统的avidin-biotin方法,优势如下:

    ★ 操作更简单,一步操作;不含生物素,不需要做亲和素和生物素的两次封闭步骤, 

    ★ 灵敏度更高:二抗上面共轭结合了大量的HRP分子,相较于传统的 avidin-biotin步骤,灵敏度高出3-5倍

    ★ 节约一抗的用量

    ★ 即用型试剂盒

 

产品信息:

  VCTS001   50 Tests   Mouse VisUCyte HRP Polymer-DAB Cell & Tissue Staining Kit
  VCTS002   50 Tests   Mouse/Rabbit VisUCyte HRP Polymer-DAB Staining Kit
  VCTS003   50 Tests   Rabbit VisUCyte HRP Polymer-DAB Cell & Tissue Staining Kit
  VCTS004   50 Tests   Goat VisUCyte HRP Polymer-DAB Cell & Tissue Staining Kit
  VCTS005   50 Tests   Rat VisUCyte HRP Polymer-DAB Cell & Tissue Staining Kit
  VCTS006   50 Tests   Sheep VisUCyte HRP Polymer-DAB Cell & Tissue Staining Kit

 

常见FAQ:

My tissue stained with the VisUCyte™ HRP polymer seems to be overstained, what could I improve to avoid this?

We would recommend lowering the concentration of the primary antibody used. Due the high sensitivity of VisUCyte™ HRP Polymer, the working concentration of primary antibodies may be 23 times lower compared to the conventional avidin-biotin-HRP protocol.

 

What is the recommended procedure for reducing background on tissue sample which appears overstained after using R&D Systems VisUCyte™ HRP polymer?  

R&D Systems recommend reducing the concentration of the primary antibody, and/or shortening the amount of time the tissue is incubated with our VisUCyte™ HRP polymer reagent.

 

Cell and Tissue Staining Kits

Are deparaffinization and antigen retrieval performed prior to starting IHC detection using Cell and Tissue Staining Kits (for example, Catalog # CTS019)?

Yes, perform deparaffinization and, if necesary, antigen retrieval prior to treating samples with primary antibody, and then use the Cell and Tissue Staining Kit for detection.

 

Immunohistochemistry Reagents

Is antigen retreival required for IHC?

Antigen retrieval is something to consider if initial IHC staining is negative.  Somtimes fixation and processing can block epitopes, and antigen retrieval can reveal these eptiopes.  For a review of antigen retreival considerations, please consult the "Resources" tab on R&D Systems' website.  Antigen retrieval information is listed under the "Protocols-Troubleshooting-Guides" link.

 

Staining Reagents

 

My tissue stained with the VisUCyte™ HRP polymer seems to be overstained, what could I improve to avoid this?

What is the recommended procedure for reducing background on tissue sample which appears overstained after using R&D Systems VisUCyte™ HRP polymer?  

R&D Systems recommend reducing the concentration of the primary antibody, and/or shortening the amount of time the tissue is incubated with our VisUCyte™ HRP polymer reagent.

 

 