The NaM87-1F6 monoclonal antibody specifically binds to blood group A expressed on human erythrocytes. Clone NaM87-1F6 induces agglutination of human group A red blood cells. It does not react with human group B, or group O red blood cells.
商品描述
NaM87-1F6
The NaM87-1F6 monoclonal antibody specifically binds to blood group A expressed on human erythrocytes. Clone NaM87-1F6 induces agglutination of human group A red blood cells. It does not react with human group B, or group O red blood cells.
同种型
Mouse IgG3, κ
克隆号
克隆 NaM87-1F6 (RUO)
浓度
0.5 mg/ml
产品详情
FITC
Fluorescein (FITC) is part of the BD blue family of dyes. This is a small organic fluorochrome with an excitation maximum (Ex Max) at 494-nm and an emission maximum (Em Max) at 518-nm. FITC is designed to be excited by the Blue laser (488-nm) and detected using an optical filter centered near 520 nm (e.g., a 530/30-nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
FITC
494 nm
518 nm
BD化合物表
{}
应用
实验应用
Flow cytometry (Routinely Tested)
反应种属
Human (QC Testing)
目标/特异性
Blood group A antigen
制备和贮存
存储溶液
Aqueous buffered solution containing protein stabilizer and ≤0.09% sodium azide.
保存方式
Aqueous buffered solution containing protein stabilizer and ≤0.09% sodium azide.
文献
文献
研发参考(3)
1. Blanchard D, Bruneau V, Bernard D, et al. Flow cytometry analysis of dual red blood cell populations after bone marrow transplantation. Br J Haematol. 1995; 89(4):741-747. (Clone-specific: Flow cytometry).
2. David B, Bernard D, Navenot JM, Muller JY, Blanchard D. Flow cytometric monitoring of red blood cell chimerism after bone marrow transplantation. Transfus Med. 1999; 9(3):209-217. (Clone-specific: Flow cytometry).
3. Walker RH, ed. Technical Manual of the American Association of Blood Banks. Arlington VA: 1990.
参考图片
Flow cytometric analysis of Human Blood Group A expression on human red blood cells. Human red blood cells were stained with either FITC Mouse IgG3, κ Isotype Control (Cat. No. 555578; dashed line histogram) or PE Mouse Anti-Human Blood Group A antibody (Cat. No. 550807; solid line histogram). The fluorescence histogram showing Human Blood Group A expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of erythrocytes.
Flow cytometric analysis of Human Blood Group A expression on human red blood cells. Human red blood cells were stained with either FITC Mouse IgG3, κ Isotype Control (Cat. No. 555578; dashed line histogram) or PE Mouse Anti-Human Blood Group A antibody (Cat. No. 550807; solid line histogram). The fluorescence histogram showing Human Blood Group A expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of erythrocytes.
Flow cytometric analysis of Human Blood Group A expression on human red blood cells. Human red blood cells were stained with either FITC Mouse IgG3, κ Isotype Control (Cat. No. 555578; dashed line histogram) or PE Mouse Anti-Human Blood Group A antibody (Cat. No. 550807; solid line histogram). The fluorescence histogram showing Human Blood Group A expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of erythrocytes.