BD Pharmingen™ Alexa Fluor®647 Mouse Anti-Human CD4
1/3

BD Pharmingen™ Alexa Fluor®647 Mouse Anti-Human CD4

分享
品牌: BD Pharmingen
pdf 下载产品说明书
pdf 下载SDS
用小程序,查商品更便捷
收藏
对比对比
咨询咨询
    反应种属:
    Human (QC Testing)
    Human (QC Testing)
    来源宿主:
    Mouse IgG1, κ
    Mouse IgG1, κ
    展开
    产品介绍
    产品信息
    抗原名称
    CD4
    宿主
    Mouse IgG1, κ
    简单描述
    The RPA-T4 monoclonal antibody specifically binds to CD4, a 59 kDa single-chain transmembrane glycoprotein that is expressed on T-helper/inducer cell populations. CD4 is also expressed on thymocyte subsets and at lower levels on monocytes and macrophages. CD4 functions as a co-receptor in MHC class II-restricted antigen-induced T cell activation and as a receptor for human immunodeficiency viruses (HIV). This antibody binds to the D1 domain (CDR1 and CDR3 epitopes) of the CD4 antigen and reacts with approximately 80% of thymocytes and 45% of peripheral blood lymphocytes. RPA-T4 is capable of blocking HIV-1, gp120, and inhibits syncytium formation.
    商品描述
    RPA-T4 The RPA-T4 monoclonal antibody specifically binds to CD4, a 59 kDa single-chain transmembrane glycoprotein that is expressed on T-helper/inducer cell populations. CD4 is also expressed on thymocyte subsets and at lower levels on monocytes and macrophages. CD4 functions as a co-receptor in MHC class II-restricted antigen-induced T cell activation and as a receptor for human immunodeficiency viruses (HIV). This antibody binds to the D1 domain (CDR1 and CDR3 epitopes) of the CD4 antigen and reacts with approximately 80% of thymocytes and 45% of peripheral blood lymphocytes. RPA-T4 is capable of blocking HIV-1, gp120, and inhibits syncytium formation.
    同种型
    Mouse IgG1, κ
    克隆号
    克隆 RPA-T4 (RUO)
    产品详情
    Alexa Fluor™ 647
    Alexa Fluor™ 647 Dye is part of the BD red family of dyes. This is a small organic fluorochrome with an excitation maximum (Ex Max) at 653-nm and an emission maximum (Em Max) at 669-nm. Alexa Fluor 647 is designed to be excited by the Red laser (627-640 nm) and detected using an optical filter centered near 520-nm (e.g., a 660/20 nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
    应用
    实验应用
    Flow cytometry (Routinely Tested)
    推荐用量
    5 µl
    反应种属
    Human (QC Testing)
    目标/特异性
    CD4
    背景
    别名
    L3T4; T-cell surface antigen T4/Leu-3; W3/25; CD4 antigen (p55)
    制备和贮存
    存储溶液
    Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
    保存方式
    Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
    文献
    文献
    研发参考(3) 1. Knapp W. W. Knapp .. et al., ed. Leucocyte typing IV : white cell differentiation antigens. Oxford New York: Oxford University Press; 1989:1-1182. 2. Piatier-Tonneau D. CD4 workshop panel report. In: Kishimoto T. Tadamitsu Kishimoto .. et al., ed. Leucocyte typing VI : white cell differentiation antigens : proceedings of the sixth international workshop and conference held in Kobe, Japan, 10-14 November 1996. New York: Garland Pub.; 1997:49-54. 3. Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995.
    数据库链接
    Entrez-Gene ID
    920

    参考图片

    Profile of peripheral blood lymphocytes analyzed by flow cytometry.

    Multiparameter flow cytometric analysis of CD4 expression on human peripheral blood leucocytes populations. Whole blood was stained with either Alexa Fluor™ 647 Mouse IgG1 κ Isotype Control (Cat. No. 557714; Left Plot) or Alexa Fluor™ 647 Mouse Anti-Human CD4 antibody (Cat. No. 557707; Right Plot). Erythrocytes were lysed with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899). Bivariate pseudocolor density plots showing CD4 expression (or Ig Isotype control staining) versus side light-scatter (SSC-A) signals were derived from gated events with the forward and side light-scattering characteristics of intact leucocyte populations. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software.

    Profile of peripheral blood lymphocytes analyzed by flow cytometry.

    声明 :本官网所有报价均为常温或者蓝冰运输价格,如有产品需要干冰运输,需另外加收干冰运输费。
    货号:
    557707
    一键复制
    询价
    100Tst
    选择数量
    当前规格1件起购 
    配送至