首页 试剂盒 CBA流式检测试剂盒 CBA kit
BD™ Cytometric Bead Array (CBA) Human Th1/Th2 Cytokine Cytometric Bead Array (CBA) Kit


品牌: BD Pharmingen









产品介绍
产品信息
简单描述
The BD™ CBA Human Th1/Th2 Cytokine Kit (Catalog No. 550749) can be used to quantitatively measure Interleukin-2 (IL-2), Interleukin-4 (IL-4), Interleukin-5 (IL-5), Interleukin-10 (IL-10), Tumor Necrosis Factor (TNF), and Interferon-γ (IFN-γ) protein levels in a single sample. The kit performance has been optimized for analysis of specific cytokines in tissue culture supernatants, EDTA plasma, and serum samples. The kit provides sufficient reagents for the quantitative analysis of 80 samples.

克隆号
(RUO)

BD化合物表
- 描述数量/尺寸零件号EntrezGene ID
- C) Human Th1/Th2 Cytokine StandardsN/A51-2428KCN/A
- E1) PE Positive Control DetectorN/A51-2429KCN/A
- B Human Th1/Th2 PE Detection ReagentN/A51-2427KCN/A
- Human IFN-γ Capture Beads1 Each (1 ea)51-9005727N/A
- Human TNF Capture Beads1 Each (1 ea)51-9005724N/A
- Human IL-10 Capture Beads80 Tests (1 ea)51-9005740N/A
- Human IL-5 Capture Beads1 Each (1 ea)51-9005718N/A
- Human IL-4 Capture Beads1 Each (1 ea)51-9005715N/A
- Human IL-2 Capture Beads80 Tests (1 ea)51-9005736N/A
- D Cytometer Setup Beads1 Each (1 ea)51-9005731N/A
- BD(tm) CBA Serum Enhancement Buffer (H)N/A51-9002150N/A
- G Assay Diluent1 Each (1 ea)51-2432KCN/A
- F Wash Buffer1 Each (1 ea)51-2431KCN/A
- E2 FITC Positive Control Detector1 Each (1 ea)51-9005734N/A
- E1 PE Positive Control Detector1 Each (1 ea)51-9005732N/A
应用
目标/特异性
IL-2, IL-4, IL-5, IL-10, TNF, IFN-γ

文献
文献
研发参考(13)
1. Bishop JE, Davis KA. A flow cytometric immunoassay for β2-microglobulin in whole blood. J Immunol Methods. 1997; 210:79–87. (Biology).
2. Camilla C, Defoort JP, Delaage M, et al. A new flow cytometry-based multi-assay system 1, Application to cytokine immunoassays. Cytometry Suppl. 1998; 8:132. (Biology).
3. Carson R, Vignali D. Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay. J Immunol Methods. 1999; 227:41–52. (Biology).
4. Chen, R, L Lowe, et al. Simultaneous quantification of six human cytokines in a single sample using microparticle-based flow cytometric technology. Clin Chem. 1999; 9:1693-1694. (Biology).
5. Collins DP, Luebering BJ, Shaut DM. T-lymphocyte functionality assessed by analysis of cytokine receptor expression, intracellular cytokine expression, and femtomolar detection of cytokine secretion by quantitative flow cytometry. Cytometry. 1998; 33:249-255. (Biology).
6. Cook, EB, JL Stahl, et al. Simultaneous measurement of six cytokines in a single sample of human tears using microparticle-based flow cytometry: allergics vs non-allergics. J Immunol Methods. 2001; 254:109-118. (Biology).
7. Dotti, G, B Salvodo, et al. Adenovector-induced expression of human-CD40-ligand (hCD40L) by multiple myeloma cells: A model for immunotherapy. Exp Hematol. 2001; 29:952-961. (Biology).
8. Fulton RJ, McDade RL, Smith PL, Kienker LJ, Kettman JR Jr. Advanced multiplexed analysis with the FlowMetrix system. Clin Chem. 1997; 43:1749-1756. (Biology).
9. Kricka LJ. Diamandis EP, Christopoulos TK, ed. Immunoassay. Academic Press; 1996:389-404.
10. Lund-Johansen F, Davis K, Bishop J, de Waal Malefyt R. Flow cytometric analysis of immunoprecipitates: high-throughput analysis of protein phosphorylation and protein-protein interactions. Cytometry. 2000; 39(4):250-259. (Biology).
11. McHugh TM. Flow microsphere immunoassay for the quantitative and simultaneous detection of multiple soluble analytes. Methods Cell Biol. 1994; 33:613-629. (Biology).
12. Oliver KG, Kettman JR, Fulton RJ. Multiplexed analysis of human cytokines by use of the FlowMetrix system. Clin Chem. 1998; 44:2057-2060. (Biology).
13. Stall, A, Q Sun, et al. A single tube flow cytometric multibead assay for isotyping mouse monoclonal antibodies, Abstract LB77. Experimental Biology Meeting. 1998. (Biology).

参考图片
Resolution of the individual bead populations in the BD CBA Human Th1/Th2 Cytokine Kit. Each population corresponds to an individual analyte.
声明 :本官网所有报价均为常温或者蓝冰运输价格,如有产品需要干冰运输,需另外加收干冰运输费。