老带新
Mouse Th1/Th2 Cytokine Cytometric Bead Array (CBA) Kit
1/2

Mouse Th1/Th2 Cytokine Cytometric Bead Array (CBA) Kit

分享
品牌: BD Pharmingen
pdf 下载产品说明书
用小程序,查商品更便捷
收藏
对比对比
咨询咨询
反应种属:
Mouse
产品介绍
产品介绍
产品信息
BD化合物表
  • 描述
    数量/尺寸
    零件号
    EntrezGene ID
  • Mouse IL-2 Capture Beads
    0.8 mL (1 ea)
    51-9005801
    N/A
  • Mouse IL-4 Capture Beads
    0.8 mL (1 ea)
    51-9005803
    N/A
  • Mouse IL-5 Capture Beads
    0.8 mL (1 ea)
    51-9005805
    N/A
  • Mouse IFN-γ Capture Beads
    0.8 mL (1 ea)
    51-9005807
    N/A
  • Mouse TNF Capture Beads
    0.8 mL (1 ea)
    51-9005809
    N/A
  • B) Mouse Th1/Th2 PE Detection Reagent
    N/A
    51-2523KC
    N/A
  • Mouse Th1/Th2 Cytokine Standards
    N/A
    51-2524KC
    N/A
  • D Cytometer Setup Beads
    1 Each (1 ea)
    51-9005731
    N/A
  • E1 PE Positive Control Detector
    1 Each (1 ea)
    51-9005732
    N/A
  • E2 FITC Positive Control Detector
    1 Each (1 ea)
    51-9005734
    N/A
  • F Wash Buffer
    1 Each (1 ea)
    51-2431KC
    N/A
  • G Assay Diluent
    1 Each (1 ea)
    51-2432KC
    N/A
应用
反应种属
Mouse
文献
文献
研发参考(13) 1. Bishop JE, Davis KA. A flow cytometric immunoassay for β2-microglobulin in whole blood. J Immunol Methods. 1997; 210:79–87. (Biology). 2. Camilla C, Defoort JP, Delaage M, et al. A new flow cytometry-based multi-assay system 1, Application to cytokine immunoassays. Cytometry Suppl. 1998; 8:132. (Biology). 3. Carson R, Vignali D. Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay. J Immunol Methods. 1999; 227:41–52. (Biology). 4. Chen, R, L Lowe, et al. Simultaneous quantification of six human cytokines in a single sample using microparticle-based flow cytometric technology. Clin Chem. 1999; 9:1693-1694. (Biology). 5. Collins DP, Luebering BJ, Shaut DM. T-lymphocyte functionality assessed by analysis of cytokine receptor expression, intracellular cytokine expression, and femtomolar detection of cytokine secretion by quantitative flow cytometry. Cytometry. 1998; 33:249-255. (Biology). 6. Cook, EB, JL Stahl, et al. Simultaneous measurement of six cytokines in a single sample of human tears using microparticle-based flow cytometry: allergics vs non-allergics. J Immunol Methods. 2001; 254:109-118. (Biology). 7. Dotti, G, B Salvodo, et al. Adenovector-induced expression of human-CD40-ligand (hCD40L) by multiple myeloma cells: A model for immunotherapy. Exp Hematol. 2001; 29:952-961. (Biology). 8. Fulton RJ, McDade RL, Smith PL, Kienker LJ, Kettman JR Jr. Advanced multiplexed analysis with the FlowMetrix system. Clin Chem. 1997; 43:1749-1756. (Biology). 9. Kricka LJ. Diamandis EP, Christopoulos TK, ed. Immunoassay. Academic Press; 1996:389-404. 10. Lund-Johansen F, Davis K, Bishop J, de Waal Malefyt R. Flow cytometric analysis of immunoprecipitates: high-throughput analysis of protein phosphorylation and protein-protein interactions. Cytometry. 2000; 39(4):250-259. (Biology). 11. McHugh TM. Flow microsphere immunoassay for the quantitative and simultaneous detection of multiple soluble analytes. Methods Cell Biol. 1994; 33:613-629. (Biology). 12. Oliver KG, Kettman JR, Fulton RJ. Multiplexed analysis of human cytokines by use of the FlowMetrix system. Clin Chem. 1998; 44:2057-2060. (Biology). 13. Stall, A, Q Sun, et al. A single tube flow cytometric multibead assay for isotyping mouse monoclonal antibodies, Abstract LB77. Experimental Biology Meeting. 1998. (Biology).

参考图片

声明 :本官网所有报价均为常温或者蓝冰运输价格,如有产品需要干冰运输,需另外加收干冰运输费。
货号:
551287
一键复制
询价
供应商现货
KIT
选择数量
当前规格1件起购 
配送至
预计5-6个工作日送达,快递: 免运费,若需干冰额外收费